A peer-reviewed journal published by K. N. Toosi University of Technology

Document Type : Research Article

Authors

Safety and Nuclear Research Reactor School, Nuclear Science and Technology Research Institute, Tehran, Iran

Abstract

In many human diseases and health cases, therapy of blood transfusion becomes necessary. In spite of the necessity, there are some risks associated with blood used in blood transfusion process. The TA-GVHD (transfusion-associated graft-versus-host-disease) is a problem when a blood transfusion occurs. The blood irradiation with gamma rays in blood bags can eliminate this risk. It should be mentioned that Co-60 sources are widely used for such blood irradiators. The present work investigates Co-60 production yield inside the external irradiation boxes of Tehran Research Reactor (TRR) using MCNPX code. 10-rod and 4-rod Co-59 assemblies were modeled at different external irradiation boxes to investigate their negative reactivity impact on TRR core as well Co-60 buildup rate during 3 years operation of the nuclear core at 4 MW power. The obtained results from MCNPX code showed a 4-rod assembly in linear form could obtain the highest specific activity (Ci.g-1) inside the external irradiation box faced to the core center. The computational results showed about 8 kCi of Co-60 is produced at the optimized irradiation position after 3 years TRR operation at 4 MW power.

Highlights

  • Kilocurie Co-60 gamma sources are used in low-scale industrial irradiator cells.
  • Kilocurie gamma sources could be produced in research reactors.
  • Selection of the best irradiation position inside the research reactor helps to obtain the highest possible yield.

Keywords

Aboufazeli, B., Tamaddoni, A., Monfared, A. S., et al. (2018). The Evaluation of Optimum Radiation Dose to Prevent Transfusion-Associated Graft-Versus-Host Disease Among the Iranian Population. Iranian Journal of Pediatrics, 28(4).
Bagheri, R. and Ranjbar, H. (2022). Nuclear designing of a blood irradiator facility for research and medical applications using Cobalt-60 line sources. Iranian Journal of Applied Physics, 12(4):7–22.
Barnard, S., Ainsbury, L., Daniels, T., et al. (2020). Alternatives to Cesium irradiators for biological sciences research and blood transfusion services. Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Contract Report CRCE-RED-001-2020.
Boghi, C., Shitsuka, D. M., Alexandruk, M., et al. (2008). Good manufacturing practices (GMP) utilized on human blood irradiation process. Exacta, 6(1):35–40.
Fensin, M. L. (2008). Development of the MCNPX depletion capability: A Monte Carlo linked depletion method that automates the coupling between MCNPX and CINDER90 for high fidelity burnup calculations. University of Florida.
Fernandes,ˆA., Antonio, A. L., Oliveira, B., et al. (2012). Effects of gamma rays on sugars composition of wild mushrooms from the Northeast of Portugal. In International Conference of Agricultural Engineering, 8-12 July 2012.
Gallmeier, F. X., Ferguson, P. D., Lu, W., et al. (2010). The CINDER’90 transmutation code package for use in accelerator applications in combination with MCNPX. Technical report, Oak Ridge National Lab.(ORNL), Oak Ridge, TN (United States). Spallation.
IAEA (2004). Gamma irradiators for radiation processing, International Atomic Energy Agency Vienna, Austria. Technical report.
Khalafi, H. and Gharib, M. (2005). Optimization of Co-60 production using neutron flux trap in the Tehran research reactor. Annals of Nuclear Energy, 32(3):331–341.
Mackenzie, C. and Smith, K. (2018). University of California System wide Radioactive Source Replacement Workgroup Recommendations. Technical report.
Menarebazari, Z. A., Jafari, H., and Gholamzadeh, Z. (2023). The design and construction of a collimator holder to equip beam tube D of the Tehran research reactor. Nuclear Engineering and Design, 405:112226.
Mhatre, S. G., Shinde, S., Bhat, R., et al. (2008). Dosimetry of blood irradiator-2000.
Mohammadyari, P., Zehtabian, M., Sina, S., et al. (2014). Dosimetry of gamma chamber blood irradiator using PAGAT gel dosimeter and Monte Carlo simulations. Journal of Applied Clinical Medical Physics, 15(1):317–330.
Moroff, G., Leitman, S., and Luban, N. (1997). Principles of blood irradiation, dose validation, and quality control. Transfusion, 37(10):1084–1092.
Nagaraj, S., Singh, V., Jayanna, H. S., et al. (2013). 60Co-Gamma Ray Induced Total Dose Effects on P-Channel MOSFETs. Indian Journal of Materials Science, 2013.
Pelowitz, D. B. (2008). MCNPX users manual, version 2.6. 0, LA-CP-07-1473. Los Alamos National Laboratory, Los Alamos (NM).
Use, R. S. (2008). Replacement: Abbreviated Version. Sciences Committee on Radiation Source Use and Replacement, National Research Council.
Van Tuyle, G. J., Strub, T. L., O’Brien, H. A., et al. (2003). Reducing RDD Concerns Related to Large Radiological Source Applications. Los Alamos National Laboratory Los Alamos, NM, USA.
Villiers, W. d. (2003). Manual for reactor produced radioisotopes. IAEA TECDOC, 1340:139.