Assessing the impact of boron distribution simplification on BNCT dosimetry

Document Type : Research Article

Author

Department of Physics‎, ‎K.N‎. ‎Toosi University of Technology‎, ‎P.O‎. ‎Box 15875-4416‎, ‎Tehran‎, ‎Iran

Abstract
‎Accurate dose calculation in boron neutron capture therapy (BNCT) requires an appropriate representation of intratumoral boron distribution‎. ‎Although assuming a uniform boron concentration simplifies dosimetric modeling‎, ‎the extent to which this approximation affects dose estimates under spatially heterogeneous conditions remains unclear‎. ‎This study investigated the effects of intratumoral boron distribution on BNCT dosimetry using Monte Carlo simulations‎. ‎A spherical tumor embedded in a Snyder head phantom was modeled with either a uniform boron concentration of 40 ppm or four concentric‎, ‎equal-volume regions with heterogeneous concentrations‎. ‎The heterogeneous models had mean tumor boron concentrations of 25‎, ‎30‎, ‎and 35 ppm‎, ‎with concentration gradients directed either from the tumor center toward its boundary or in the reverse direction‎. ‎Depth-dose profiles‎, ‎the area under the dose-depth curve (AUC) within the tumor‎, ‎and the ratio of maximum tumor dose to maximum healthy-tissue dose were evaluated‎. ‎Compared with the uniform 40-ppm reference‎, ‎the heterogeneous models exhibited lower tumor-region AUC values‎, ‎with reductions ranging from 5.94% to 41.17%‎. ‎For a given mean boron concentration‎, ‎the center-to-boundary configuration yielded a higher AUC than the boundary-to-center configuration‎. ‎The relative AUC difference between these configurations decreased from 29.16% at a mean concentration of 25 ppm to 9.44% at 35 ppm‎. ‎These findings demonstrate that the dosimetric impact of intratumoral boron distribution depends on both the mean boron concentration and its spatial arrangement‎, ‎highlighting the importance of considering distribution patterns when simplifying boron uptake in BNCT dose calculations‎.

Highlights

  • Simplifying intratumoral boron distribution can affect BNCT dose calculations.
  • Boron gradient direction influences the tumor dose distribution.
  • Gradient orientation has a stronger impact at lower mean boron concentrations.
  • Tumor AUC varies with the spatial arrangement of boron.
  • Boron distribution affected BNCT dosimetry through both concentration and spatial arrangement.

Keywords

Subjects

Copyright
RPE is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0).

Conflict of Interest
The authors declare no potential conflict of interest regarding the publication of this work‎.

Funding
‎The authors declare that no funds‎, ‎grants‎, ‎or other financial support were received during the preparation of this manuscript‎.


Articles in Press, Accepted Manuscript
Available Online from 23 November 2026

  • Receive Date 15 October 2026
  • Revise Date 19 November 2026
  • Accept Date 21 November 2026