Aldawood, S., Thirolf, P., Miani, A., et al. (2017). Development of a Compton camera for prompt-gamma medical imaging. Radiation Physics and Chemistry, 140:190-197.
Alispach, C., Borkowski, J., Cadoux, F. R., et al. (2020). Large scale characterization and calibration strategy of a SiPM-based camera for gamma-ray astronomy. Journal of Instrumentation, 15(11):P11010.
Berti, A., Chiavassa, A., Corti, D., et al. (2020). Development and test of a SiPM cluster for a SiPM version of the Cherenkov Telescope Array LST camera. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 982:164373.
Boo, J., Hammig, M. D., and Jeong, M. (2021). Row Column Readout Method to Mitigate Radiographic-Image Blurring From Multipixel Events in a Coded-Aperture Imaging System. IEEE Transactions on Nuclear Science, 68(5):1175-1183.
CAEN (2011). CAEN Digital pulse height analyser- a digital approach to radiation spectroscopy, application note AN2508. CAEN Digital pulse height analyser.
Cates, J. W., Bieniosek, M. F., and Levin, C. S. (2017). Highly multiplexed signal readout for a time-of-flight positron emission tomography detector based on silicon photomultipliers. Journal of Medical Imaging, 4(1):011012.
Cozzi, G., Busca, P., Carminati, M., et al. (2016). Development of a SiPM-based detection module for prompt gamma imaging in proton therapy. In 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD), pages 1{5. IEEE.
Czyz, S. A. and Farsoni, A. T. (2017). A radioxenon detection system using CdZnTe, an array of SiPMs, and a plastic scintillator. Journal of Radioanalytical and Nuclear Chemistry, 313(1):131-140.
Frach, T., Prescher, G., Degenhardt, C., et al. (2009). The digital silicon photomultiplierprinciple of operation and intrinsic detector performance. In 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC), pages 1959-1965. IEEE.
Gnecchi, S., Barry, C., Bellis, S., et al. (2019). Long distance ranging performance of Gen3 LiDAR imaging system based on 1_ 16 SiPM array. In Proceedings of the International Image Sensors Society (IISS) Workshop, Snowbird, UT, USA, pages 23-27.
Gnecchi, S. and Jackson, C. (2017). A 1_ 16 SiPM array for automotive 3D imaging LiDAR systems. In Proceedings of the 2017 International Image Sensor Workshop (IISW), Hiroshima, Japan, pages 133{136.
Henningsen, F., Boehmer, M., Eller, P., et al. (2021). A self-monitoring precision calibration light source for the IceCube Upgrade. Journal of Instrumentation, 16(09):C09033.
Huang, T., Fu, Q., Lin, S., et al. (2017). NaI (Tl) scintillator read out with SiPM array for gamma spectrometer. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 851:118{124.
Jeong, M. and Hammig, M. (2020). Development of hand-held coded-aperture gamma ray imaging system based on GAGG (Ce) scintillator coupled with SiPM array. Nuclear Engineering and Technology, 52(11):2572-2580.
Jiang, S., Lu, J., Meng, S., et al. (2021). A prototype of sipm-based scintillator compton camera with capacitive multiplexing readout. Journal of Instrumentation, 16(01):P01027.
Kim, H., Kao, C.-M., Hua, Y., et al. (2021). Multiplexing readout for time-of-flight (TOF) PET detectors using striplines. IEEE Transactions on Radiation and Plasma Medical Sciences, 5(5):662{670.
Kitsmiller, V. J. and OSullivan, T. D. (2019). Next-generation frequency domain di_use optical imaging systems using silicon photomultipliers. Optics Letters, 44(3):562{565.
Knoll, G. F. (2010). Radiation detection and measurement. John Wiley & Sons.
Lavelle, C., Shanks, W., Chiang, C., et al. (2019). Approaches for single channel large area silicon photomultiplier array readout. AIP Advances, 9(3):035123.
Lee, H., Lee, T., and Lee, W. (2020). Development of a position-sensitive 4_ Compton camera based on a single segmented scintillator. IEEE Transactions on Nuclear Science, 67(12):2511{2522.
Liang, Z., Hu, T., Li, X., et al. (2020). A cosmic ray imaging system based on plastic scintillator detector with SiPM readout. Journal of Instrumentation, 15(07):C07033.
Maira, G., Chiarelli, A. M., Brafa, S., et al. (2020). Imaging System Based on Silicon Photomultipliers and Light Emitting Diodes for Functional Near-Infrared Spectroscopy. Applied Sciences, 10(3):1068.
Press, W. H., Teukolsky, S. A., Vetterling, W. T., et al. (2007). Numerical recipes 3rd edition: The art of scientic computing. Cambridge university press.
Shimazoe, K., Yoshino, M., Ohshima, Y., et al. (2020). Development of simultaneous PET and Compton imaging using GAGG-SiPM based pixel detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 954:161499.
Sun, Y. and Maricic, J. (2016). Sipms characterization and selection for the DUNE far detector photon detection system. Journal of Instrumentation, 11(01):C01078.
T_etrault, M.-A., Lamy, E. D., Boisvert, A., et al. (2015). Real-time discrete SPAD array readout architecture for time of ight ET. IEEE Transactions on Nuclear Science, 62(3):1077{1082.
Xiong, H., Zhou, R., Chen, J., et al. (2019). Design and performance of analog circuit for the wide field of view Cherenkov telescope array of LHAASO. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 925:156{163.
Yang, Q., Kuang, Z., Sang, Z., et al. (2019). Performance comparison of two signal multiplexing readouts for SiPM-based pet detector. Physics in Medicine & Biology, 64(23):23NT02.