K. N. Toosi University of TechnologyRadiation Physics and Engineering2645-63971220200601Investigation the effect of anode's insert material on spatial distribution of X-ray source in plasma focus device156347410.22034/rpe.2020.63474ENSeyed Milad MiremadDepartment of Nuclear Engineering, Faculty of Advanced Science & Technologies, University of Isfahan, Isfahan, IranBabak Shirani BidabadiDepartment of Nuclear Engineering, Faculty of Advanced Science & Technologies, University of Isfahan, Isfahan, IranJournal Article20180412In this paper, the effect of anode's insert material on spatial distribution of X-ray emission zone of plasma focus device was studied. Anode's insert materials were fabricated out of aluminum, zinc, tin, tungsten and lead. For each insert material at the constant operating voltage of 21 kV, the image of pinhole camera which monitors the surface and the top of anode was recorded at the various pressures of 0.3, 0.6, 0.9 and 1.2 mbar. The results indicated that the X-ray emission zone above the anode surface not only includes thermal radiation of plasma, but also depends on anode's insert materials. This zone could be due to the passage of high energy electrons from the vapor of anode's material above the anode's surface.https://rpe.kntu.ac.ir/article_63474_0cd7b93072614bdb9e03c11899c895bd.pdfK. N. Toosi University of TechnologyRadiation Physics and Engineering2645-63971220200601Determination of coagulation time of in vivo cut bleeding treated by non-thermal atmospheric pressure plasma7116347510.22034/rpe.2020.63475ENZahra Shahbazi RadRadiation Application Department, Shahid Beheshti University, P.O. Box 1983969411, Tehran, IranFereydoun Abbasi DavaniRadiation Application Department, Shahid Beheshti University, P.O. Box 1983969411, Tehran, IranGholamreza EtaatiPhysics and Energy Engineering Department, Amirkabir University, Hafiz Avenue, Tehran, IranSamaneh SeifiNuclear Physics Department, Physics Faculty, Shahrood University of Technology, Shahrood, IranJournal Article20180401The aim of this research was determination of the required time for coagulation of in vivo cut bleeding treated by non-thermal atmospheric pressure plasma. To meet this, an atmospheric pressure plasma jet device was designed and constructed. Helium was used as working gas. The electrical parameters and optical emission spectrum of helium plasma were measured. The averaged treatment time to coagulate the incision bleeding on the mouse liver was obtained 8.6 μs, and the average time of naturally incision bleeding coagulation was 10 min.https://rpe.kntu.ac.ir/article_63475_1471fcf6db8165aeb06075d0b2c2bb67.pdfK. N. Toosi University of TechnologyRadiation Physics and Engineering2645-63971220200601Study of PWR transients by coupling of ANSYS-CFX with a kinetic model13216347710.22034/rpe.2020.63477ENHossein SharifianNuclear Engineering Department, Shahid Beheshti University, G.C, P.O. Box 1983963113, Tehran, IranMahdi AghaieNuclear Engineering Department, Shahid Beheshti University, G.C, P.O. Box 1983963113, Tehran, IranAhmad ZolfaghariNuclear Engineering Department, Shahid Beheshti University, G.C, P.O. Box 1983963113, Tehran, IranJournal Article20171002In this work, dynamic responses of a WWER-1000 reactor in reactivity insertions are studied using a coupling method. The ANSYS-CFX is implemented for thermal hydraulic study of the core and the point kinetic equation (PKE) is coupled as a FORTRAN subroutine. For transient analysis of the core, the thermal feedback of the fuel is added to coolant, and numerical solver of cylindrical heat transfer for obtaining the irradiated fuel rod temperature profile is also included. In order to investigate the irradiation effect, the fuel and gap properties in burnup with appropriate correlations could be calculated. Using memory management system (MMS) and data transfer arrays, coupling between numerical subroutines is carried out. It is shown that the dynamic response of the core depends on burnup, and the response could be varied in time. In addition, the coupling method is reliable for other dynamic calculations.https://rpe.kntu.ac.ir/article_63477_4ce8545dfb2f3f22d26e884117162cab.pdfK. N. Toosi University of TechnologyRadiation Physics and Engineering2645-63971220200601The use of artificial neural networks to distinguish naturally occurring radioactive materials from unauthorized radioactive materials using a plastic scintillation detector23266347810.22034/rpe.2020.63478ENReza Ziyaee SisakhtFaculty of Nuclear Engineering, Shahid Beheshti University, Tehran, IranFereydoun Abbasi DavaniFaculty of Nuclear Engineering, Shahid Beheshti University, Tehran, IranRouhollah GhaderiFaculty of Nuclear Engineering, Shahid Beheshti University, Tehran, IranJournal Article20170926Distinguishing naturally occurring radioactive (<em>e.g.</em> ceramics, fertilizers, etc.) from unauthorized materials (<em>e.g.</em> high enriched uranium, Pu-239, etc.) to reduce false alarms is a prominent characteristic of radiation monitoring port. By employing the energy windowing method for the spectrum correspond to the simulation of a plastic scintillator detector using the MCNPX Monte Carlo code together with an artificial neural network, the present work proposes a method for distinguishing naturally occurring materials and K-40 from four unauthorized sources including high enriched uranium and Pu-239 (as special nuclear materials), Cs-137 (as an example of dirty bombs), and depleted uranium.https://rpe.kntu.ac.ir/article_63478_dadb4f05ed1687be259e6eb9df44d9ad.pdfK. N. Toosi University of TechnologyRadiation Physics and Engineering2645-63971220200601Analysis of the fusion hindrance phenomenon for 58Ni+54Fe fusion reaction using cold nuclear matter properties27336347910.22034/rpe.2020.63479ENReza GharaeiDepartment of Physics, Faculty of Science, Hakim Sabzevari University, P.O. Box 397, Sabzevar, IranJournal Article20170930The role of saturation property of cold nuclear matter is examined in order to describe the steep falloff phenomenon of the measured fusion cross sections at energies far below the Coulomb barrier for <sup>58</sup>Ni+<sup>54</sup>Fe colliding system. For this aim, the double-folding microscopic approach which is modified by modeling the repulsive core effects in the nucleon-nucleon interactions is used to calculate the nuclear interaction potential. Moreover, the theoretical values of the fusion cross section, <em>S</em> factor, and the logarithmic derivative are computed using the coupled-channel technique, including couplings to the low-lying 2<sup>+</sup> and 3<sup>-</sup> states in target and projectile. The results obtained reveal that the corrective effects of cold nuclear matter can be responsible for the description of the fusion hindrance phenomenon in our chosen system.https://rpe.kntu.ac.ir/article_63479_2f955a825a07b32dea6183c4089d4e1b.pdfK. N. Toosi University of TechnologyRadiation Physics and Engineering2645-63971220200601Analytical range evaluation for therapeutic protons in stack of materials35396348010.22034/rpe.2020.63480ENFatemeh Sadat RasouliDepartment of Physics, K.N. Toosi University of Technology, P.O. Box 15875-4416, Tehran, Iran0000-0002-1383-9660Journal Article20180307As one of the most clinically relevant parameters in proton radiotherapy, the range of incident particles can be measured either by counting the number of protons or through depth-dose evaluation in the target. In the latter, the range is defined as the depth in the target at the distal 80% point of the Bragg peak. In this work, a highly accurate analytical model was employed to predict depth-dose distribution, and hence the range, in a desired target. Aiming to study the effect of energy spread on the range, proton beams with initial Gaussian distributions have been considered. For our arbitrary tested energies, the results show that the more the width of energy distribution increases, the more the Bragg peaks shift in depth, by about -0.25% to -25%, compared with those of monoenergetic beams. Furthermore, it was found that for different widths of initial energy spectrum, keeping the mean energy the same, the range remains unchanged. It was also shown that the results corresponding to utilizing analytical range determination for proton beams of different incident energies in stack of materials deviate from those of Monte Carlo simulations by less than 1.7%. The results are encouraging, although accurate modeling of analytical proton dose distribution in the presence of tissue inhomogeneities is still an unsolved problem.https://rpe.kntu.ac.ir/article_63480_d08c5d6c4f08c50d5e15f8b974a4edf6.pdf