Payvand Taherparvar; Ali AziziGanjgah
Abstract
Low energy I-125- seeds are considered as a common source in different brachytherapy techniques for treatment of different cancers. In this study, at first, we simulated and validated I-125 (model 6711) seed according to the TG-43U1 recommendation, by GEANT4 Monte Carlo toolkit. Moreover, we simulated ...
Read More
Low energy I-125- seeds are considered as a common source in different brachytherapy techniques for treatment of different cancers. In this study, at first, we simulated and validated I-125 (model 6711) seed according to the TG-43U1 recommendation, by GEANT4 Monte Carlo toolkit. Moreover, we simulated new seeds containing cylindrical Ag+Al2O3 markers with different ratio of Ag and Al2O3 in the final composition of the marker and compared the radial dose functions and anisotropy functions of the sources. For validation and evaluation purposes, the radial dose function and anisotropy function were calculated at various distances from the center of the different simulated sources. The source validation results show that GEANT4 Monte Carlo toolkit produces accurate results for dosimetric parameters of the I-125 seed by choosing the appropriate physics list. On the other hand, results show a similarity between calculated dosimetric parameters of the I-125 seed (6711) and other sources, with a percentage difference of about 5%.
Milad Payandeh; Mahdi Sadeghi; Dylan Richeson; Somayeh Gholami
Abstract
It is important to have accurate information regarding the dose distribution for treatment planning and to accurately deposit that dose in the tissue surrounding the brachytherapy source. However, the practical measurement of dose distribution for various reasons is associated with several problems. ...
Read More
It is important to have accurate information regarding the dose distribution for treatment planning and to accurately deposit that dose in the tissue surrounding the brachytherapy source. However, the practical measurement of dose distribution for various reasons is associated with several problems. In this study, 6711 I-125, Micro Selectron mHDR-v2r Ir-192, and Flexisource Co-60 sources were simulated using the MCNP5 Monte Carlo method. To simulate the sources, the exact geometric characteristics of each source, the material used in them, and the energy spectrum of each source were entered as input to the program, and finally, the dosimetric parameters including dose rate constant, radial dose function, and anisotropy function were calculated for considered seeds according to AAPM, TG-43 protocol recommendation. Results obtained for dosimetric parameters of dose rate constant, radial dose function, and anisotropy function for I-125, Ir-192, and Co-60 sources agreed with other studies. According to the good agreement obtained between the parameters of TG43 and other studies, now these datasets can be used as input in the treatment planning systems and to validate their calculations.